Scientia Agricultura Sinica ›› 2017, Vol. 50 ›› Issue (7): 1302-1316.doi: 10.3864/j.issn.0578-1752.2017.07.013

• HORTICULTURE • Previous Articles     Next Articles

Frost Hardiness Assessment of Floribunda Roses by Means of Electrical Impedance Tomography

JIAO Meiling1, GONG Ruijuan1,2, QIAN Ji1, ZHANG Gang1   

  1. 1College of Horticulture, Agriculture University of Hebei, Baoding 071001, Hebei; 2Cotton Research Institute, Hebei Academy of Agriculture and Forestry Science, Shijiazhuang 050051
  • Received:2016-08-22 Online:2017-04-01 Published:2017-04-01

Abstract: 【Objective】 The objective of this experiment is to study whether the electrical impedance tomography (EIT) is feasible to assess the frost hardiness of floribunda roses (Rosa hybrida Hort. ‘Floribunda’), and with the view to provide a new reference method for rapid and non-destructive detection of ornamental plant for frost hardiness. 【Method】 Three perennial floribunda roses ‘Hongmao’, ‘Rouqingsishui’ and ‘Xianjing’ were used to measure EIT and electrical impedance spectroscopy (EIS) parameters of one-year-old stems under natural conditions of low temperature as well as artificial freezing, and the correlations of frost hardiness assessed by means of EIT and EIS parameters were compared with that of the traditional electrolyte leakage (EL) method. Meanwhile, the correlation analysis of four EIS parameters specific extracellular resistance (re), specific intracellular resistance (ri), relaxation time (t) and distribution coefficient of t (y) of stems for three varieties of floribunda roses and EIT reconstructed values were studied.【Result】 The order of frost hardiness of the three floribunda roses varieties was: ‘Xianjing’>‘Rouqingsishui’>‘Hongmao’. Stems of the three varieties could achieve a clear EIT imaging at different temperatures and EIT reconstructed value showed a decreasing trend as temperature decreased. Frost hardiness calculated by EIT reconstructed value had a significant correlation (r=0.92) with that assessed by EL method, however, the results were lower than the EL method. EIS parameters changed during cold acclimation, on the whole, the extracellular resistance (re) rose, while the relaxation time (t) dropped. Under natural conditions of low temperature, re and EIT reconstructed values of ‘Hongmao’ and ‘Xianjing’ positively correlated (r>0.72), and t and EIT reconstructed value of ‘Rouqingsishui’ and ‘Xianjing’ positively correlated (r>0.63) as well, indicating that all of them can be used to characterize the state of cell and tissue.【Conclusion】 Under freezing temperature test, after frost damage EIT reconstructed values of stems in floribunda roses reduced significantly, and could be calculated with Logistic equation to get the frost hardiness, but the results were lower than those of EL method. Under natural conditions of low temperature, two EIS parameters extracellular resistance (re) and relaxation time (t) had correlations with EIT reconstructed values. After freezing test, the frost hardiness of the floribunda roses could be assessed by the EIT reconstructed values of stems.

Key words: floribunda roses, frost hardiness, electrical impedance tomography, electrical impedance spectroscopy parameters

[1]    任超世. 生物电阻抗测量技术. 中国医疗器械信息, 2004, 10(1): 21-25.
REN C S. Electrical bioimpedance measurement technology. China Medical Device Information, 2004, 10(1): 21-25. (in Chinese)
[2]    BAYFORD R H. Bioimpedance tomography (electrical impedance tomography). Annual Review of Biomedical Engineering, 2006, 8: 63-91.
[3]    董秀珍. 生物电阻抗成像研究的现状与挑战. 中国生物医学工程学报, 2008, 27(5): 641-643, 649.
DONG X Z. Recent progress and challenges in the study of bioimpedance imaging. Chinese Journal of Biomedical Engineering, 2008, 27(5): 641-643, 649. (in Chinese)
[4]    尤富生, 董秀珍, 史学涛, 付峰, 刘锐岗, 秦明新, 汤孟兴, 李兴. 电阻抗断层成像硬件系统的初步研究. 中国体视学与图像分析, 2003, 8(2): 114-118.
YOU F S, DONG X Z, SHI X T, FU F, LIU R G, QIN M X, TANG M X, LI X. Preliminary research on the hardware system of electrical impedance tomography. Chinese Journal of Stereology and Image Analysis, 2003, 8(2): 114-118. (in Chinese)
[5]    徐桂芝, 杨硕, 李颖, 颜威利. 电阻抗断层成像技术综述. 河北工业大学学报, 2004, 33(2): 35-40.
XU G Z, YANG S, LI Y, YAN W L. The development of electrical impedance tomography. Journal of Hebei University of Technology, 2004, 33(2): 35- 40. (in Chinese)
[6]    王雷, 刘锐岗, 周伟, 董秀珍. 磁感应断层成像硬件系统与实验的研究进展. 医疗卫生装备, 2013, 34(2): 85-88.
WANG L, LIU R G, ZHOU W, DONG X Z. Research progress     of magnetic induction tomography system and experimental    results. Chinese Medical Equipment Journal, 2013, 34(2): 85-88. (in Chinese)
[7]    林磊, 莫玉龙, 侯卫东. 电阻抗成像系统的设计和实现. 计算机工程, 2002, 28(7): 75-76, 127.
LIN L, MO Y L, HOU W D. Design and implementation of electrical impedance tomography system. Computer Engineering, 2002, 28(7): 75-76, 127. (in Chinese)
[8]    周旭胜. 基于matlabEIT图像重构算法研究[D]. 南京: 南京理工大学, 2010.
ZHOU X S. EIT image reconstruction algorithms based on matlab [D]. Nanjing: Nanjing University of Science and Technology, 2010. (in Chinese)
[9]    HENDERSON R P, WEBSTER J G. An impedance camera for spatially specific measurements of the thorax. IEEE Transactions on Biomedical Engineering, 1978, 25: 250-254.
[10]   BROWN B H, SEAGAR A D. The sheffield data collection system. Clinical Physicsand Physiological Measurement, 1987, 8(Suppl. A): 91-97.
[11]   任超世, 王妍, 邓娟. 电阻抗断层成像应用技术研究. 中国医疗器械杂志, 2007, 31(4): 1-4.
REN C S, WANG Y, DENG J. The application technique of electrical impedance tomography. Chinese Journal of Medical Instrumentation, 2007, 31(4): 1-4. (in Chinese)
[12]   KOUKOURLIS C S, KYRIACOU G A, SAHALOS J N. A 32- electrode data collection system for electrical impedance tomography. IEEE Transactions on Biomedical Engineering, 1995, 42(6): 632-636.
[13]   YAIR G, ANTONI I, BORIS R. A new concept for medical imaging centered on cellular phone technology. Public Library of Science ONE, 2008, 3(4): e2075.
[14]   王超, 王化祥. 医学电阻抗成像系统电极结构优化设计. 第四军医大学学报, 2001, 22(1): 78-80.
WANG C, WANG H X. Optimum design of the structure of electrode for clinical EIT system. Journal of the Fourth Military Medical University, 2001, 22(1): 78-80. (in Chinese)
[15]   帅万钧, 董秀珍, 付峰, 尤富生, 徐灿华, 晁勇, 吕晓宁. 基于电阻抗断层成像技术的图像监护软件系统的设计与实现. 中国医疗设备, 2012, 27(3): 14-16, 5.
SHUAI W J, DONG X Z, FU F, YOU F S, XU C H, CHAO Y, LÜ X N. Design and implement of software system for image monitoring based on electrical impedance tomography. China Medical Devices, 2012, 27(3): 14-16, 5. (in Chinese)
[16]   董秀珍, 秦明新, 汤孟兴, 史学涛, 尤富生, 刘锐岗. 电阻抗断层成像系统及重构算法. 第四军医大学学报, 1999, 20(3): 218-219, 263.
DONG X Z, QIN M X, TANG M X, SHI X T, YOU F S, LIU R G. Electrical impedance tomography (EIT) system and its reconstruction algorithm. Journal of the Fourth Military Medical University, 1999, 20(3): 218-219, 263. (in Chinese)
[17]   付峰, 董秀珍, 刘锐岗, 尤富生, 史学涛. 实时电阻抗断层成像系统的成像算法及软件系统实现. 医疗设备信息, 2003, 18(6): 2-4.
FU F, DONG X Z, LIU R G, YOU F S, SHI X T. Research on real-time electrical impedance tomography: Algorithm and systematic implementation. Information of Medical Equipment, 2003, 18(6): 2-4. (in Chinese)
[18]   杨琳, 徐灿华, 付峰, 代萌, 董秀珍. 一种基于加权频差阻尼最小二乘的准静态EIT算法. 仪器仪表学报, 2013, 34(8): 1879-1885.
YANG L, XU C H, FU F, DAI M, DONG X Z. Quasi-static EIT algorithm based on weighted frequency difference damped least square. Chinese Journal of Scientific Instrument, 2013, 34(8): 1879-1885. (in Chinese)
[19]   DAI M, LI B, HU S J, XU C H, YANG B, LI J B, FU F, FEI Z, DONG X Z. In vivo imaging of twist drill drainage for subdural hematoma: A clinical feasibility study on electrical impedance tomography for measuring intracranial bleeding in humans. Public Library of Science ONE, 2013, 8(1): e55020.
[20]   FU F, LI B, DAI M, HU S J, LI X, XU C H, WANG B, YANG B, TANG M X, DONG X Z, FEI Z, SHI X T. Use of electrical impedance tomography to monitor dehydration treatment of cerebral edema: A clinical study. Public Library of Science ONE, 2014, 9(12): e113202.
[21]   陈晓艳, 吴君, 王化祥, 李达. 不同体位呼吸过程的电阻抗断层成像研究. 生物医学工程杂志, 2010, 27(5): 1004-1007.
CHEN X Y, WU J, WANG H X, LI D. Research on respiration course of human at different postures by electrical impedance tomography. Journal of Biomedical Engineering, 2010, 27(5): 1004-1007. (in Chinese)
[22]   任超世, 王妍, 赵舒. 电阻抗断层成像与胃排空和胃动力检测. 世界华人消化杂志, 2008, 16(8): 799-805.
REN C S, WANG Y, ZHAO S. Electrical impedance tomography measuring gastric emptying and gastric motility. World Chinese Journal of Digestology, 2008, 16(8): 799-805. (in Chinese)
[23]   王刘环, 弓瑞娟, 张钢. 抗寒锻炼期间丰花月季的电阻抗参数与抗寒性的关系. 河北农业大学学报, 2014, 38(1): 48-52.
WANG L H, GONG R J, ZHANG G. Relation between electrical impedance spectroscopy parameters and frost hardiness in stems of floribunda roses during frost hardening. Journal of Agricultural University of Hebei, 2014, 38(1): 48-52. (in Chinese)
[24]   金明丽, 徐继忠, 张钢. 苹果砧木枝条电阻抗参数与其抗寒性的关系. 园艺学报, 2011, 38(6): 1045-1051.
JIN M L, XU J Z, ZHANG G. Relation between electrical impedance spectroscopy parameters and frost hardiness in shoots of apple rootstocks. Acta Horticulturae Sinica, 2011, 38(6): 1045-1051. (in Chinese)
[25]   史学涛, 霍旭阳, 尤富生, 付峰, 刘锐岗, 徐灿华, 董秀珍. 颅内出血电阻抗成像系统及初步动物实验. 航天医学与医学工程, 2007, 20(1): 24-27.
SHI X T, HUO X Y, YOU F S, FU F, LIU R G, XU C H, DONG X Z. Electrical impedance imaging system for intracranial hemorrhage and its preliminary animal experiment. Space Medicine and Medical Engineering, 2007, 20(1): 24-27. (in Chinese)
[26]   游宇. 电阻抗断层成像技术在脑缺血早期监测中的实验研究[D]. 西安: 第四军医大学, 2008.
YOU Y. Experimental study of electrical impedance tomography on early cerebral ischemia monitoring [D]. Xi’an: The Fourth Military Medical University, 2008. (in Chinese)
[27]   尤富生, 董秀珍, 秦明新. 电阻抗断层成像硬件系统. 国外医学生物医学工程分册, 1998, 21(3): 134-139.
YOU F S, DONG X Z, QIN M X. Hardware system of electrical impedance tomography. Foreign Medical Sciences (Biomedical Engineering Fascicle), 1998, 21(3): 134-139. (in Chinese)
[28]   . 生物电阻抗断层成像系统在猪脑内血肿模型急性期实时监护的初步研究[D]. 西安: 第四军医大学, 2008.
WANG L. Initial study of electrical impedance tomography (EIT) in the hemorrhage model of piglets [D]. Xi’an: The Fourth Military Medical University, 2008. (in Chinese)
[29]   ZHANG G, RYYPPO A, REPO T. The electrical impedance spectroscopy of Scots pine needles during cold acclimation. Physiologia Plantarum, 2002, 115: 385-392.
[30]   范少然, 崔睿航, 武东霞, 焦美玲, 张钢. 抗寒锻炼期间丰花月季茎中矿质元素含量与EIS参数变化及其关系研究. 植物生理学报, 2016, 52(3): 325-333.
FAN S R, CUI R H, WU D X, JIAO M L, ZHANG G. Research on the changes of mineral elements content and EIS parameters in floribunda rose stems and their relationship during cold acclimation. Plant Physiology Journal, 2016, 52(3): 325-333. (in Chinese)
[31]   REPO T, ZHANG M, RYYPPO A, VAPAAVUORI E, SUTINEN S. Effects of freeze-thaw injury on parameters of distributed electrical circuits of stems and needles of Scots pine seedlings at different stages of acclimation. Journal of Experimental Botany, 1994, 45(6): 823-833.
[32]   REPO T, LAPPI J. Estimation of standard error of impedance- estimated frost resistance. Scandinavian Journal of Forest Research, 1989, 4(1/4): 67-74.
[33]   张钢, 肖建忠, 陈段芬. 测定植物抗寒性的电阻杭图谱法. 植物生理与分子生物学学报, 2005, 31(1): 19-26.
ZHANG G, XIAO J Z, CHEN D F. Electrical impedance spectroscopy method for measuring cold hardiness of plants. Journal of Plant Physiology and Molecular Biology, 2005, 31(1): 19-26. (in Chinese)
[34]   简令成, 王红. 逆境植物细胞生物学. 北京: 科学出版社, 2009: 115-123.
JIAN L C, WANG H. Plant Cell Biology in Stress. Beijing: Science Press, 2009: 115-123. (in Chinese)
[35]   MACDONALD J R. Impedance Spectroscopy. New York: John Wiley & Sons, Inc, 1987: 346.
[36]   REPO T, KORHONEN A, LAUKKANEN M, LEHTO T, SILVENNOINEN R. Detecting mycorrhizal colonisation in Scots pine roots using electrical impedance spectra. Biosystems Engineering, 2014, 121: 139-149.
[37]   向地英, 邸葆, 张钢, 弓瑞娟. 镉胁迫对黄栌叶片电阻抗参数及相对电导率的影响. 河北农业大学学报, 2014, 37(2): 58-64.
XIANG D Y, DI B, ZHANG G, GONG R J. Effects of cadmium stress on electrical impedance spectroscopy parameters and relative electrolyte leakage in leaves of Cotinus coggygria Scop. Journal of Agricultural University of Hebei, 2014, 37(2): 58-64. (in Chinese)
[38]   孟昱, 弓瑞娟, 邸葆, 向地英, 张钢, 徐成立, 李云飞. 涝胁迫下白桦叶和茎含水量的电阻抗图谱估测. 植物学报, 2014, 49(1): 105-113.
MENG Y, GONG R J, DI B, XIANG D Y, ZHANG G, XU C L, LI Y F. Electrical impedance spectroscopy estimation of water content  in leaves and stems of white birch (Betula platyphylla) under flooding stress. Chinese Bulletin of Botany, 2014, 49(1): 105-113. (in Chinese)
[39]   姚琳, 张钢. NaCl胁迫下流苏的电阻抗与电导分析. 林业科学, 2011, 47(12): 60-68.
YAO L, ZHANG G. Electrical impedance and electrolyte leakage analysis of Chinese fringetree (Chionanthus retusus) under NaCl stress. Scientia Silvae Sinicae, 2011, 47(12): 60-68. (in Chinese)
[40]   REPO T, KORHONEN A, LEHTO T, SILVENNOINEN R. Assessment of frost damage in mycorrhizal and non-mycorrhizal roots of Scots pine seedlings using classification analysis of their electrical impedance spectra. Trees, 2016, 30(2): 483-495.
No related articles found!
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!